@ -29,7 +29,7 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
public MonitorDataRefreshBusiness()
|
|
|
|
|
{
|
|
|
|
|
// 启动定时器,每隔1秒刷新一次报表数据
|
|
|
|
|
refreshTimer = new Timer(RefreshData, null, 0, 1600);
|
|
|
|
|
refreshTimer = new Timer(RefreshData, null, 0, 2000);
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
/// <summary>
|
|
|
|
|
@ -47,6 +47,7 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
//解析返回的信号数据
|
|
|
|
|
//RGV小车号
|
|
|
|
|
ushort[] rgvNo = new ushort[7];
|
|
|
|
|
//RGV状态信号
|
|
|
|
|
ushort[] rgvState = new ushort[7];
|
|
|
|
|
@ -90,11 +91,13 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
transferSingal.WriteAlarmSignal();
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
bool isRefresh = false;
|
|
|
|
|
|
|
|
|
|
//报表信号获取
|
|
|
|
|
for (int i = 0; i < 7; i++)
|
|
|
|
|
{
|
|
|
|
|
rgvNo[i] = PlcConnect.MelsecInstance2.ByteTransform.TransUInt16(signals, (i * 2) + 20);
|
|
|
|
|
rgvState[i] = PlcConnect.MelsecInstance2.ByteTransform.TransUInt16(signals, i * 2);
|
|
|
|
|
rgvNo[i] = PlcConnect.MelsecInstance2.ByteTransform.TransUInt16(signals, (i * 2) + 20);
|
|
|
|
|
if (i > 2)
|
|
|
|
|
{
|
|
|
|
|
weights[i - 3] = PlcConnect.MelsecInstance2.ByteTransform.TransSingle(signals, ((i - 3) * 4) + 38);
|
|
|
|
|
@ -109,7 +112,7 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
// 监控画面信息插入
|
|
|
|
|
if (MonitorInsert(RecipeSendBusiness.NowRecipeCode, RecipeSendBusiness.NowDeviceNo, rgvNo[0]))
|
|
|
|
|
{
|
|
|
|
|
MonitorMainPage.MonitorRefreshAction.Invoke();
|
|
|
|
|
isRefresh = true;
|
|
|
|
|
}
|
|
|
|
|
transferSingal.WriteStationReportSignal(1); // 复位信号
|
|
|
|
|
}
|
|
|
|
|
@ -126,7 +129,7 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
entity.BaseEndTime = DateTime.Now;
|
|
|
|
|
if (ZxDailyReportService.Instance.UpdateDailyReportInfo(entity))
|
|
|
|
|
{
|
|
|
|
|
MonitorMainPage.MonitorRefreshAction.Invoke();
|
|
|
|
|
isRefresh = true;
|
|
|
|
|
}
|
|
|
|
|
transferSingal.WriteStationReportSignal(2); // 复位信号
|
|
|
|
|
}
|
|
|
|
|
@ -144,9 +147,8 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
entity.MidEndTime = DateTime.Now;
|
|
|
|
|
if (ZxDailyReportService.Instance.UpdateDailyReportInfo(entity))
|
|
|
|
|
{
|
|
|
|
|
MonitorMainPage.MonitorRefreshAction.Invoke();
|
|
|
|
|
isRefresh = true;
|
|
|
|
|
}
|
|
|
|
|
MonitorMainPage.MonitorRefreshAction.Invoke();
|
|
|
|
|
transferSingal.WriteStationReportSignal(3); // 复位信号
|
|
|
|
|
}
|
|
|
|
|
n2:
|
|
|
|
|
@ -171,7 +173,7 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
}
|
|
|
|
|
if (ZxDailyReportService.Instance.UpdateDailyReportInfo(entity))
|
|
|
|
|
{
|
|
|
|
|
MonitorMainPage.MonitorRefreshAction.Invoke();
|
|
|
|
|
isRefresh = true;
|
|
|
|
|
}
|
|
|
|
|
transferSingal.WriteStationReportSignal(i + 1); // 复位信号
|
|
|
|
|
}
|
|
|
|
|
@ -194,15 +196,20 @@ namespace HighWayIot.Winform.Business
|
|
|
|
|
}
|
|
|
|
|
if (ZxDailyReportService.Instance.UpdateDailyReportInfo(entity))
|
|
|
|
|
{
|
|
|
|
|
MonitorMainPage.MonitorRefreshAction.Invoke();
|
|
|
|
|
isRefresh = true;
|
|
|
|
|
}
|
|
|
|
|
transferSingal.WriteStationReportSignal(7); // 复位信号
|
|
|
|
|
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if (isRefresh == true)
|
|
|
|
|
{
|
|
|
|
|
MonitorMainPage.MonitorRefreshAction.Invoke();
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
catch (Exception ex)
|
|
|
|
|
{
|
|
|
|
|
Log4net.LogHelper.Instance.Error("报表解析方法出现错误", ex);
|
|
|
|
|
Log4net.LogHelper.Instance.Error("前端监控报表解析方法出现错误", ex);
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
|